Measured Parameters

• (4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
• (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
• 1 MHz High Speed Sampling, 14 bit ADC, 1% FS
• Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
• Phase Lock Loop – Generator tracking
• Phase Lock Loop – Standard PQ mode
• Monitoring/Compliance
• IEEE 1159
• IEC 61000-4-30 Class A
• EN50160 Quality of Supply
• Current Inrush / Energization
• Voltage Fault recording
• Long Term Monitoring
• Continuous Data Logging w/min/max/avg

Power Quality Triggers

• Cycle-by-cycle analysis
• 256 samples/cycle; 1/2 cycle RMS steps (1)
• L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)
• RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
• Waveshape Recordings (2/6/2 cycles)
• Low and Medium Frequent Transients – V&I
• High Frequency Transients – V&I, 3% FS trigger (1)
• Harmonics Summary Parameters
• Cross trigger V & I channels
• RMS Event Characterization (IEEE or IEC)
• Transient Event Characterization (1)

Distortion/Power/Energy

• W, VA, VAR, TPF, DPF, Demand, Energy, etc.
• IEEE 1459 Parameters of distorted and unbalanced
• Harmonics/Interharmonics per IEC 1000-4-7
• THD/Harmonic Spectrum (V,I,W) to 63rd
• TID /Interharmonic Spectrum (V,I) to 63rd
• Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
• Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
• Unbalance (max. rms deviation) & sequencing components
• 5 User Spec Harmonics or Signaling Frequency
• Vector/Arithmetic/Coincident Parameters

General Specifications

• Size (HxWxD): 12″ x 2.5″ x 8″ (30cm x 6.4cm x 20.3 cm)
• Weight: 4.2 pounds (1.9 kg)
• Operating Temperature: 0 -50 (32 to 122 )
• Storage Temperature: -20 to 55 (4 to 131 F)
• Humidity: 10 to 90% non-condensing
• System Time Clock-Crystal controlled-1 second resolution
• Charger /Battery Eliminator: 90-264 VAC 47-63 Hz
• Display: LCD color touch screen